How do you verify the fire resistance of a PIR sandwich panel roof?

Start with the fire requirements in the building design and the function the roof must perform. A PIR roof panel can meet specific requirements where the evidence covers the selected product and assembly. Check three separate properties: reaction to fire of the product, fire resistance of the roof assembly and performance under external fire exposure. Identify the structure, joints and service penetrations the design calls for. A classification for a similar warehouse gives little guidance unless its configuration matches yours. Keep the records accessible so changes to equipment or openings can be assessed after handover.