What does A2-s1,d0 mean for a mineral wool wall panel?

Mineral wool panels

At a glance

A2-s1,d0 describes the reaction to fire of the finished panel. It is not the wall’s EI fire resistance rating. The mineral wool core, steel facings and other components form a product assessed as a whole. Read the full designation, then check the wall requirements and conditions of installation. The wool may have its own classification as a material, but that class does not automatically carry over to the panel. Its facings, coatings and the bond between layers are part of the product. When ordering, check the declaration for the complete element in the specified configuration.

Detail of an intact mineral wool core between thin steel facings

Distinguish the core from the finished panel

Many mineral wool wall panel data sheets list A2-s1,d0. This does not permit independent changes to adhesive, coating or joint construction. The documents define what is covered. A photo of a fibrous core is no evidence of the fire performance of second-hand or clearance stock.

Read each part of the classification

A2 indicates a very limited contribution to fire growth under the specified tests. The suffix s1 indicates low smoke production by the classification criteria. The suffix d0 indicates that the product meets the criterion for absence of flaming droplets or particles in the relevant test. Read the three parts together.

Do not read s1 as a promise of no smoke in an actual fire, or d0 as a description of every possible fire scenario. The class reports properties of a tested product. It neither predicts a particular fire nor guarantees the safety of an entire building.

Distinguish reaction to fire from EI

Fire resistance describes an assembly’s ability to retain stated functions for a specified time under test conditions. In EI, E means integrity and I means insulation. The number gives the classification time. The result belongs to a particular wall construction.

A favourable reaction-to-fire class does not confer an EI rating. Thickness, joint geometry, supports, fixings and seals matter. If the design calls for a particular EI class, confirm that the whole arrangement is covered. A non-combustible core is not sufficient evidence.

R appears when the assessment also covers loadbearing capacity in fire. Do not add R to the wall designation merely because the panel carries wind load in normal service. Use the class for the specific element and function assessed.

Check the field of application

Check panel orientation, span, side of fire exposure and support conditions. A result for one arrangement need not cover another. Span limits and prescribed joint components are part of the evidence even if they are missing from a brief sales sheet.

NPD against fire resistance means no performance is declared for that characteristic. It is not approval for an application requiring a fire resistance class. Nor does it mean there is no reaction-to-fire classification. Read each characteristic in its own row and context.

Maintain continuity across the wall

Doors, cable penetrations and ventilation ducts interrupt the wall field. Their details must preserve the intended separation. Junctions with the floor, slab above and adjacent wall matter just as much: the protective function extends beyond the panels on the order.

Do not replace the specified seal with ordinary installation foam. Check the effect of any new opening before cutting, including during subsequent maintenance. Tell building users which walls perform a protective function and which alterations require technical review.

Prepare the handover documents

Collect the declaration of performance, applicable classification documents and approved detail drawings. Check the delivery against the order. Record the fixings and seals actually installed. Handover evidence should describe the as-built wall rather than a maximum catalogue rating.

Inspect and photograph connections before concealment, especially wall ends and service penetrations. Resolve substitutions before handover. A clear record helps assess a future repair without guessing what lies behind the flashing.

Questions and answers

Are A1 and A2 the same?

No. They are separate reaction-to-fire classes. Do not transfer the wool’s class to the finished panel. Use the designation in the product’s own documentation.

Does EI 120 guarantee two hours of safety in every fire?

No. It classifies a defined construction under test conditions and within a stated field of application. Real fires vary, and the wall must match the classified assembly.

7 branches. Materials closer to your project.

  • SEROCK — Dzierżenin 34 E [mapa]
  • BŁONIE — ul. Sochaczewska 138A [mapa]
  • RADOM — ul. Grobickiego 8 [mapa]
  • ŁÓDŹ — Natolin 8 [mapa]
  • OLSZTYN — Barczewo, ul. Prosta 9 [mapa]
  • WROCŁAW — ul. Jerzmanowska 10C [mapa]
  • GORZÓW WLKP. — ul. Zielona 33/34 [mapa]
Mapa oddziałów: Olsztyn, Serock, Błonie, Łódź, Radom, Wrocław i Gorzów Wlkp.

Free quote

What to include in your enquiry

Tell us how you plan to use the material, the dimensions and the quantity you need. Include the thickness, grade or variant name, along with the delivery town or your preferred collection branch. For a specific product, add its name or a link to the product page. We will reply to the email address you provide to discuss availability and the terms of your order.

Read next