How do you check whether a roof has enough fall for sandwich panels?

Sandwich panel roofs

At a glance

A roof that looks flat still needs a reliable drainage path. For a sandwich panel roof, check the minimum pitch for the actual panel system, joints and rooflights. Measure support levels and allow for deflection to find the fall the finished roof will have. Percentage fall is the difference in height divided by the horizontal run, multiplied by 100. A drop of 432 mm over a horizontal distance of 7.2 m gives a fall of 6%, or about 3.4°. Confusing that percentage with an angle of 6° produces a different roof geometry.

Low-pitched panel roof sloping towards the gutter beneath a bright sky

Measure the fall correctly

On a retrofit, survey actual support levels as well as consulting the old drawing. Check each run, particularly by outlets and wall abutments. A satisfactory average fall can conceal a local hollow where water collects. Relate the survey to the expected movement under load.

Put the unit beside every pitch dimension on the drawing. If the design uses degrees and the panel data sheet uses percentages, show the conversion so that successive support heights can be set correctly.

Read the system conditions in full

For example, one family of steel-faced PIR roof panels specifies more than 5% for continuous panels without rooflights. With end laps or rooflights it specifies more than 7%. These conditions apply to that particular product family.

In that example, a measured 6% clears the first threshold but falls below the second. Check tolerances and the other system conditions too. Where the requirement says “greater than”, a value exactly on the limit is insufficient. Confirm against current documentation for the offered panel before ordering.

Allow for deflection and tolerances

Both the panel and its supporting frame deflect under load. On a low-pitched roof, a small change in shape can alter drainage. Check the relevant design load cases and service conditions for the complete supporting system.

Installation tolerances affect local fall. Use measured differences in support height and have any correction specified by the designer before installation. Do not force panels against misaligned supports to level the frame.

Assess joints and obstructions

At an end lap, water must flow over the joint. Overlap, core cutback, seals and bearing must follow the system detail. Obtain the permitted overlap length for the selected panel. Also review junctions at walls, rooflights and rooftop equipment.

An obstruction may divert runoff onto adjacent panels or trap debris. Check flashing geometry and cleaning access. Review planned additions before cutting the roof. Even a small opening needs a sealed detail, a load path and protection for exposed edges.

Trace the entire drainage route

Size gutters, outlets and overflows for the catchment and building geometry. Include any discharge from a higher roof. Inspect the eaves to ensure water can leave every profile trough. A flashing that dams the outlet can defeat an otherwise adequate panel pitch.

Provide planned access for cleaning. Leaves, deposits and snow can restrict drainage. Where parapets enclose the roof, check the emergency drainage detail in the design. Arrange inspections from safe, designated access points.

Approve the roof layout before manufacture

Before ordering, confirm the panel model, joints, lengths and required pitch against drawings and frame measurements. If the proposed arrangement lies outside the system conditions, revise the geometry or select a suitable roof system. Extra sealant cannot extend the approved use.

At handover check levels, terminations, joints and clear drainage paths. Record measurements and photograph details. Inspect after early rainfall using the planned access. If water stands, investigate the actual geometry and cause.

Questions and answers

Can a sandwich panel roof be laid without any fall?

Only consider that arrangement if the specific system expressly permits it. Typical roof panels require a pitch and effective drainage to the manufacturer’s instructions.

Are 5% and 5° the same pitch?

No. A 5% fall is about 2.9°. The percentage relates the height difference to the horizontal run. Degrees express the angle.

7 branches. Materials closer to your project.

  • SEROCK — Dzierżenin 34 E [mapa]
  • BŁONIE — ul. Sochaczewska 138A [mapa]
  • RADOM — ul. Grobickiego 8 [mapa]
  • ŁÓDŹ — Natolin 8 [mapa]
  • OLSZTYN — Barczewo, ul. Prosta 9 [mapa]
  • WROCŁAW — ul. Jerzmanowska 10C [mapa]
  • GORZÓW WLKP. — ul. Zielona 33/34 [mapa]
Mapa oddziałów: Olsztyn, Serock, Błonie, Łódź, Radom, Wrocław i Gorzów Wlkp.

Free quote

What to include in your enquiry

Tell us how you plan to use the material, the dimensions and the quantity you need. Include the thickness, grade or variant name, along with the delivery town or your preferred collection branch. For a specific product, add its name or a link to the product page. We will reply to the email address you provide to discuss availability and the terms of your order.

Read next