Panels · Sheet metal · Insulation · Accessories

Specifying corrugated roofing for an industrial building. How to assess substitutions

A roofing specification should enable the contractor to order the correct sheet and assess any proposed alternative. Describe the intended use, required properties and installation conditions of the fibre-cement covering. A general description such as “corrugated roofing sheet” or a trade name for asbestos-free fibre cement cannot identify a complete system. Record the building use, heating, humidity, cleaning regime, emissions and planned services. State whether the building will be open-sided and how its large doors are operated. These conditions inform the choice of roof layers and fixings. A visually similar product can require a different supporting layout or different accessories.

By |2026-11-13T14:53:31+01:0013 November 2026|Metal roofing|Comments Off on Specifying corrugated roofing for an industrial building. How to assess substitutions

Industrial roofs in corrosive environments. What to check beyond the sheet

Fibre-cement sheets do not rust like steel. An industrial roof still contains metal fixings, flashings and structural members whose durability may govern the life of the covering. Select the asbestos-free sheets and these components together. Give the supplier details of airborne substances, possible liquid contact, changes in humidity and the cleaning process. Occasional deposits present different conditions from continuous wetting by an aggressive liquid. A general claim of corrosion resistance cannot establish that the entire roof is suitable for every industrial process. Confirm the resistance of the specified sheet finish, fasteners and seals for the conditions the roof will actually experience.

By |2026-11-13T14:53:30+01:0013 November 2026|Metal roofing|Comments Off on Industrial roofs in corrosive environments. What to check beyond the sheet

Photovoltaics on a corrugated industrial roof. Load paths and maintenance access

Installing photovoltaics changes the loads on an industrial roof. Before choosing a mounting system, have the sheets, purlins, fixings and primary structure assessed together. The brackets need a defined load path into the structure. Unintended bearing pressure can damage fibre-cement sheets. Check the corrugation profile and actual support positions against the original delivery documents where available. Examine cracks and damaged fixing holes while they are still accessible. Arrange any necessary roofing repairs before fitting the modules. The layout must also let rainwater drain freely and leave safe access for maintenance throughout the life of the array.

By |2026-11-13T15:03:32+01:0013 November 2026|Metal roofing|Comments Off on Photovoltaics on a corrugated industrial roof. Load paths and maintenance access

Roof penetrations for services in industrial buildings with fibre-cement sheets

Every penetration interrupts the roof covering. Plan pipes, vents and brackets with the fibre-cement sheet layout before delivery. The services contractor needs the sheet, lap and support positions. The roofer needs the equipment dimensions, its purpose and the way it will be supported. Cutting a hole wherever convenient and sealing it at the end can leave the opening in a corner, lap or fixing zone. Asbestos-free fibre cement forms the covering. Equipment loads need a route into the structure. The profile, sealing materials and access for later maintenance all affect the long-term ability of the penetration to keep water out.

By |2026-11-13T14:53:27+01:0013 November 2026|Metal roofing|Comments Off on Roof penetrations for services in industrial buildings with fibre-cement sheets

Extending an industrial building with corrugated roofing. How to join old and new

An extension changes the shape of an industrial roof, the way it drains and the loads it may experience. Survey the existing fibre-cement sheets before selecting new components. An asbestos-free sheet with a similar-looking corrugation may have an incompatible profile. Record sheet lengths, profile, surface finish, fixings, delivery records and earlier repairs. A single building may have several generations of roofing. If the composition of an old covering is uncertain, do not break or drill a sample to identify it. Establish which areas can stay, how the junction will work and how to protect the occupied building during construction.

By |2026-11-13T14:53:26+01:0013 November 2026|Metal roofing|Comments Off on Extending an industrial building with corrugated roofing. How to join old and new

Industrial roofing and reaction to fire. What does the sheet classification cover?

A roof sheet’s reaction-to-fire classification describes a particular product. Assess the fire resistance of the roof assembly separately, taking account of the structure, insulation, joints and service penetrations. An offer describing an asbestos-free fibre-cement roof as “fireproof” gives the buyer little information about what has been assessed. Look for the declared class of the exact sheet being supplied. Designations such as A1 and A2-s1,d0 describe reaction to fire under a defined classification system. A coated sheet may have a different declaration from an uncoated version. Check the actual roof build-up against the fire performance required by the design.

By |2026-11-13T14:53:25+01:0013 November 2026|Metal roofing|Comments Off on Industrial roofing and reaction to fire. What does the sheet classification cover?

Wind loading on large fibre-cement roofs

Wind forces vary across a large roof. The corners, edges, height of the building and openings in its walls all influence the loads. Select fibre-cement sheets, supports and fixings together for the particular building. The weight of an asbestos-free sheet alone tells you little about wind resistance. Follow the load path from the roof surface through the frame to its anchorage. Open terrain, neighbouring buildings, height and topography affect exposure. Trees or temporary stacks of materials may provide little shelter over the life of the roof. Base the design on lasting site conditions and the applicable design rules.

By |2026-11-13T14:53:24+01:0013 November 2026|Metal roofing|Comments Off on Wind loading on large fibre-cement roofs

Corrugated roofing sheets on steel purlins: what must the design specify?

When steel purlins support corrugated fibre-cement roofing, design the sheets, fasteners and steelwork together. Check the design loads, distances between supports and the load path through the fixings. A sheet that can be screwed to an existing profile may still be unsuitable for its span or fixing arrangement. The sheet manufacturer specifies the required supports and lap positions for each product. The steel purlins also need checks for strength and stability. Sheet length is only one input. Loads, product properties and installation details all affect which layout the designer can approve.

By |2026-11-13T14:53:22+01:0013 November 2026|Metal roofing|Comments Off on Corrugated roofing sheets on steel purlins: what must the design specify?

When does a fibre-cement roof suit a materials store?

A roof over a materials store should keep rain off the goods and leave deliveries easy to handle. Corrugated fibre cement can provide the covering for an enclosed building or an open-sided shelter. The choice depends on what is stored, how exposed the site is and how the structure carries the loads. Raw materials that tolerate brief wetting need different protection from packaging or dry mixes. Decide whether the store also needs walls or control of its indoor conditions. A durable covering still needs effective drainage, clearance for handling equipment and a way to manage moisture from the ground, incoming goods and outside air.

By |2026-11-13T14:53:21+01:0013 November 2026|Metal roofing|Comments Off on When does a fibre-cement roof suit a materials store?

Rooflights in corrugated fibre-cement roofs: matching profiles and keeping out rain

Daylight can improve working conditions in an industrial building if it reaches the right places. Lay out the rooflights in relation to workstations, racks and traffic routes. Consider glare, sun exposure of stored goods and heat gain. Opaque fibre-cement sheets and translucent rooflights perform different functions and have different support and maintenance requirements. Before ordering a rooflight, check its profile and installation details against the exact roofing system. Two sheets with similar-looking corrugations can fit poorly at their laps, and a rooflight that fits between the sheets still needs to carry its design loads.

By |2026-11-13T14:53:20+01:0013 November 2026|Metal roofing|Comments Off on Rooflights in corrugated fibre-cement roofs: matching profiles and keeping out rain
Back to top