Panels · Sheet metal · Insulation · Accessories

SIP prices and the cost of a finished wall. How to compare quotations

Two SIP wall quotations can be compared when they cover the same plan, openings, performance and state of finish. The panel price per square metre is only one item. Check who pays for drawings, cutting, fasteners, seals, transport, erection and the layers on both sides of the wall. For a given thermal resistance, a PUR or PIR core may be thinner than EPS with higher thermal conductivity. Facings and structural requirements also affect the final dimensions. Compare the quotes against a wall section and record the price, responsible party and exclusions for each item.

By |2026-11-13T21:21:29+01:0013 November 2026|PIR insulation|Comments Off on SIP prices and the cost of a finished wall. How to compare quotations

Panelised or modular homes. Where do SIPs fit in?

A home built with structural insulated panels (SIPs) can arrive as flat elements for assembly on site or as three-dimensional modules assembled in a factory. Both methods use prefabrication. Drawings, the schedule of work and the specification tell you what will arrive. That scope affects site access, unloading, installation order and when service layouts must be agreed. The SIP discussed here has OSB facings bonded to rigid PUR or PIR foam. The same type of panel can be used in either method. Compare which joints and finishes will be completed on site and who is responsible for the agreed handover condition.

By |2026-11-13T21:21:28+01:0013 November 2026|PIR insulation|Comments Off on Panelised or modular homes. Where do SIPs fit in?

SIPs in walls, roofs and floors. Can one panel do all three jobs?

Choose a structural insulated panel (SIP) for its position in the building. In a wall, loads must pass around openings. In a roof, span and protection from water are critical. A floor also has to meet vibration and acoustic requirements. Two panels with similar cross-sections can have different load capacities and fixing details. The panels discussed here have OSB facings bonded to a PUR or PIR foam core. For each assembly, check the system documentation and building design for permitted uses, supports, connections and finishes.

By |2026-11-13T21:21:27+01:0013 November 2026|PIR insulation|Comments Off on SIPs in walls, roofs and floors. Can one panel do all three jobs?

How to compare conductivity, thermal resistance and U-values for PUR, PIR and EPS SIPs

When comparing structural insulated panels, first identify what each quoted figure describes. Thermal conductivity, λ, belongs to a material. Thermal resistance, R, also depends on layer thickness. The U-value applies to a particular construction. For an OSB-faced SIP, use the foam or EPS thickness alone to calculate core resistance. A PUR or PIR core with lower declared conductivity can achieve the same resistance as a thicker EPS core. For complete walls, include facings and joint splines and compare figures calculated for the same part of the construction.

By |2026-11-13T21:21:26+01:0013 November 2026|PIR insulation|Comments Off on How to compare conductivity, thermal resistance and U-values for PUR, PIR and EPS SIPs

Structural insulated panel or OSB-faced insulation board? How to tell them apart

Two boards with foam cores and OSB faces can look alike yet perform different jobs. To establish whether a structural insulated panel (SIP) can carry wall or roof loads, look for its intended use, support arrangement and joint details in the product documentation. Check that the figures apply to the complete bonded element. For an insulation board installed on an existing structure, check the thermal properties, fixings and substrate requirements. OSB faces bonded to rigid PUR or PIR foam are one possible construction. The appearance of the board alone cannot establish its load capacity.

By |2026-11-13T21:21:25+01:0013 November 2026|PIR insulation|Comments Off on Structural insulated panel or OSB-faced insulation board? How to tell them apart

How to specify EPS insulation for a large construction project

Give each use of expanded polystyrene its own order line, identified by the zone or grid reference on the drawings. Two boards of equal thickness may face different demands under a floor, against a foundation, on a façade or beneath a roof membrane. State the required thermal, mechanical and moisture properties, dimensions and quantities for each line. Add delivery dates, required product documents and a procedure for approving substitutions. With those details, the buyer can compare like-for-like quotations and the site team can check an incoming pack against its intended location.

By |2026-11-13T21:21:23+01:0013 November 2026|PIR insulation|Comments Off on How to specify EPS insulation for a large construction project

EPS, PIR or mineral wool for a commercial building: how do you choose?

Choose insulation for each part of a commercial building by asking what the finished wall, floor or roof has to do. A repair workshop needs a floor that can carry equipment. A practice above another tenancy may need a floating screed with a tested impact sound insulation layer. A roof refurbishment may leave little depth at the threshold. Compare EPS, PIR and mineral wool at the thickness available, then check the declared properties, moisture exposure and fire performance of the proposed assembly. Price each option with the fixings, protective layers and junctions it needs.

By |2026-11-13T21:21:22+01:0013 November 2026|PIR insulation|Comments Off on EPS, PIR or mineral wool for a commercial building: how do you choose?

Is EPS suitable for a building with intermittent heating?

EPS can reduce heat loss from a workshop, warehouse or other building that is heated for only part of the week. To judge the benefit, record the operating hours, the temperature between shifts and the time available to reach the working temperature. Treat a continuously heated office and an adjoining cold store as separate zones. The time needed to warm up also depends on the mass of the floor, walls and equipment. Ventilation and moisture loads matter, especially where people or wet vehicles enter a building whose surfaces are still cold.

By |2026-11-13T21:21:20+01:0013 November 2026|PIR insulation|Comments Off on Is EPS suitable for a building with intermittent heating?

How to reduce thermal bridging where an industrial floor meets the wall

On a section through the edge of the hall, trace the insulation from beneath the floor to the base of the wall. A concrete upstand, column base or door threshold can carry heat around thick EPS boards in the floor. For a sandwich panel wall, include the bottom edge of the panel and the fixing rail. The junction must carry the loads shown on the structural drawings and keep out water. Detail the vehicle entrance separately, because wheel loads, drainage and the level of the closed door all meet at the slab edge.

By |2026-11-13T21:21:19+01:0013 November 2026|PIR insulation|Comments Off on How to reduce thermal bridging where an industrial floor meets the wall

What does an EPS board’s fire class tell you about a roof?

When specifying an EPS-insulated roof, ask for three separate pieces of information. The board’s reaction-to-fire class describes how the product behaves under defined test conditions. The fire resistance of the roof concerns the performance of the building element in fire. External fire performance concerns exposure from above. A declaration showing class E for an EPS board gives no number of minutes for the roof. Identify the actual deck, insulation, covering, fixings and junctions, then check whether the classification documents cover that combination and the way it will be installed.

By |2026-11-13T21:21:18+01:0013 November 2026|PIR insulation|Comments Off on What does an EPS board’s fire class tell you about a roof?