SOPREMA EFIGREEN ITE on large façades. Insulation continuity and brackets

PIR insulation

At a glance

Use the first window on the hall façade as a sample for the remaining bays. Show the EFIGREEN ITE insulation return at the reveal, the bracket position and the space for flashing. The actual frame-to-subframe distance determines whether the detail fits and can vary between storeys. Draw a horizontal section at the jamb and a vertical section at the sill. Together they show insulation continuity, fixing positions and the drainage path. Inspect these junctions before fitting the cladding, while the edges of the boards are accessible.

SOPREMA EFIGREEN ITE aluminium-faced PIR boards with tongue-and-groove edges

Measuring at the frame

A repeated window reference in the schedule identifies a common frame type. Check the wall face, cladding supports and sill edge on site for each distinct bay arrangement.

Identifying the façade board

Measure reveal depth on both sides of the frame and identify the datum. Mark hinges, drainage openings and flashing fixings before confirming the extent of the insulation.

Allowing for reveal width

EFIGREEN ITE is an aluminium-faced PIR board with tongue-and-groove joints. Its data sheet gives λ of 0.023 W/(m·K), CS(10/Y)150 and reaction-to-fire class D-s2,d0. Check the classification of the complete façade for the specified assembly.

Dimension the insulation, subframe and finish separately in the reveal section. Include the movement allowance specified at the frame junction. Compare their combined dimension with the smallest surveyed gap.

A bracket in the sample bay

Mark where the bracket passes through the insulation plane. Cut around the actual bracket and use the anchorage specified for the substrate. The PIR board itself does not support the weight of the cladding.

Inspecting the sill junction

Before closing the sill detail, check the junctions to the side flashings and the drainage outlet at the frame. Include insulation continuity at the lower corner in a photograph with a scale.

Board layout around windows

Set out the available 2500 × 1200 or 1200 × 1000 mm board size. Mark the tongue-and-groove orientation. Turning an offcut round can put its edge profile on the wrong side of the next bay.

Records for subsequent storeys

Record the approved window bay, photographs and actual frame-to-cladding-face dimension. If a later storey falls outside the approved detail range, flag that window for a separate detail.

7 branches. Materials closer to your project.

  • SEROCK — Dzierżenin 34 E [mapa]
  • BŁONIE — ul. Sochaczewska 138A [mapa]
  • RADOM — ul. Grobickiego 8 [mapa]
  • ŁÓDŹ — Natolin 8 [mapa]
  • OLSZTYN — Barczewo, ul. Prosta 9 [mapa]
  • WROCŁAW — ul. Jerzmanowska 10C [mapa]
  • GORZÓW WLKP. — ul. Zielona 33/34 [mapa]
Mapa oddziałów: Olsztyn, Serock, Błonie, Łódź, Radom, Wrocław i Gorzów Wlkp.

Free quote

What to include in your enquiry

Tell us how you plan to use the material, the dimensions and the quantity you need. Include the thickness, grade or variant name, along with the delivery town or your preferred collection branch. For a specific product, add its name or a link to the product page. We will reply to the email address you provide to discuss availability and the terms of your order.

Read next