Panels · Sheet metal · Insulation · Accessories

Pricing sandwich panels and cold-formed steel sections from a shared layout

Prepare a coordinated layout before comparing quotations for sandwich panels and their supporting steelwork. The panels and sections can come from different suppliers, but both orders need the same support centres, flange widths and joint positions. Show panel divisions, openings and the edges of the roof or wall on one drawing. It will identify where Z purlins, channel rails or other sections are needed and where a joint requires extra fixing space. A total length of steel gives no indication of whether each panel will land on a suitable support. Checking the drawing before ordering avoids discovering these discrepancies during installation.

By |2026-11-13T11:20:59+01:0013 November 2026|Design and specification|Comments Off on Pricing sandwich panels and cold-formed steel sections from a shared layout

Cold-formed steel sections in warehouses, production buildings and cold stores

A warehouse, a production building and a cold store can look much alike from outside. Inside, their loads, humidity, temperatures and equipment can differ considerably. Choose cold-formed sections, sandwich panels, fasteners and junction details for the way the building will be used. In a warehouse with repeated bays, Z sections can serve as roof purlins and channels as wall rails. Suitably designed sigma sections are another option. Coordinate the support grid and panel layout with industrial doors, loading bays and service runs before fabrication. This gives openings their own supports and avoids alterations to finished steelwork.

By |2026-11-13T11:20:57+01:0013 November 2026|Design and specification|Comments Off on Cold-formed steel sections in warehouses, production buildings and cold stores

Installing sandwich panels on cold-formed steel: checks before closing the envelope

Inspect the supporting steelwork before the first sandwich panels go on. Once a wall bay or roof slope is covered, connections that were easy to inspect or adjust can become inaccessible. Check that Z purlins, channel rails and other cold-formed sections provide the supports specified in the panel documentation. The steelwork and cladding crews need one handover plan showing which bays are ready, the order in which they will be closed and which connections still need access. This prevents panels from concealing unfinished structural work and lets the team schedule deliveries to match the areas actually available for installation.

By |2026-11-13T10:30:33+01:0013 November 2026|Design and specification|Comments Off on Installing sandwich panels on cold-formed steel: checks before closing the envelope

Support spacing for sandwich panels: coordinating panel and steel section data

Support spacing determines how many rails or purlins a building needs and how far its sandwich panels must span. Removing a purlin increases the panel span and can increase the load carried by each remaining purlin. Assess both components using the same layout and load assumptions before finalising the material schedule. Identify the exact roof or wall panel, including its core and facing thicknesses. Its external colour may also affect the manufacturer’s design data. Panels with similar core materials and thicknesses can have different capacities and fixing requirements, so use the documentation for the actual panel selected.

By |2026-11-13T10:30:32+01:0013 November 2026|Design and specification|Comments Off on Support spacing for sandwich panels: coordinating panel and steel section data

Galvanised steel supports for sandwich panels: coatings, moisture and insulation continuity

Steel rails behind sandwich panels are exposed to the conditions at their particular position in the building envelope. Specify corrosion protection, sealed joints and continuous insulation together. The zinc coating helps protect the steel, while seals control moisture entry and the insulation limits heat flow. An industrial building may be dry inside, intermittently humid or exposed to substances used in production. Outside, rain and pollutants add further exposure. A member beneath a leaking joint can experience much wetter conditions than the rest of the frame. Select its protective coating for that location and the intended use of the building.

By |2026-11-13T10:30:31+01:0013 November 2026|Design and specification|Comments Off on Galvanised steel supports for sandwich panels: coatings, moisture and insulation continuity

Hat sections in façade framing: what can a secondary rail support?

In addition to the main wall rails, a façade may use smaller sections to support its outer cladding. A hat section has a foot on each side and a raised crown. The feet attach to the backing while the crown provides a separate bearing surface for the cladding. Some sections have sloping sides or upturned edges on their feet. Check the width available for the fasteners as well as the overall depth. Define which component the rail supports and how its loads reach the main structure. A secondary rail must be sized for the loads it will actually carry.

By |2026-11-13T10:30:30+01:0013 November 2026|Design and specification|Comments Off on Hat sections in façade framing: what can a secondary rail support?

Sigma sections for lightweight cladding: choosing the section and detailing the connections

Selecting a cladding rail involves checking the bearing flange, fastener positions and alignment as well as section resistance. Cold-formed sigma sections have a profiled web and come in several proportions. The additional bends divide the web into shorter flats and affect the behaviour of the whole section. Many sigma sections also have lips at the outer edges of the flanges. Lip shape and length are part of the section geometry. Two sections with the same overall depth can therefore differ in both structural behaviour and usable fixing space. Assess these details against the structural design and the panel installation drawing together.

By |2026-11-13T10:30:28+01:0013 November 2026|Design and specification|Comments Off on Sigma sections for lightweight cladding: choosing the section and detailing the connections

C-section rails for sandwich wall panels: planning the support lines

Plan the wall rails around the panel layout and the way each sandwich panel spans. Cold-formed C sections can provide the supporting framework, provided their bearing surfaces, fixings and deflections are coordinated with the cladding. Corners, openings and steps in the façade all need details of their own. Vertically laid panels generally need horizontal support lines at suitable intervals. Horizontal panels may require different support positions and end details. The correct arrangement depends on the panel type, length and support conditions. When the panel orientation changes, check the rail layout again before ordering the steelwork.

By |2026-11-13T10:30:27+01:0013 November 2026|Design and specification|Comments Off on C-section rails for sandwich wall panels: planning the support lines

Z purlins for sandwich roof panels: spacing, flange width and connections

Z purlins are widely used on lightweight industrial roofs. For a sandwich panel roof, the section depth tells only part of the story. The panels must span the distance between purlins, and the top flange must provide enough bearing and space for the fasteners. Loads pass through the roof panels into the cold-formed sections. First check the panel for the proposed span, loading and support arrangement. Then check the purlin for the load it receives from its tributary strip of roof. Changing the spacing affects both checks. Even a stronger purlin leaves the panel’s permissible span to be verified.

By |2026-11-13T10:30:26+01:0013 November 2026|Design and specification|Comments Off on Z purlins for sandwich roof panels: spacing, flange width and connections

Cold-formed steel supports for sandwich panels: detailing the connection

A sandwich panel needs enough bearing width and suitable fasteners. Its supporting steel section must transfer the load from those fasteners to the main frame. Check both requirements at the same flange before selecting the rail or purlin. Start with a panel layout showing the direction of span, panel ends, openings and corners. A vertically laid wall panel needs different support lines from a horizontal one. Z, C, sigma and top-hat sections are not interchangeable simply because they have the same depth: flange geometry, fixing positions and the way the member is restrained also matter.

By |2026-11-13T09:43:26+01:0013 November 2026|Design and specification|Comments Off on Cold-formed steel supports for sandwich panels: detailing the connection